Water heater sizing calculator

Count the hot water your household uses in its busiest hour and get the first-hour rating a tank water heater needs, using the US Department of Energy worksheet.

Water heater sizingLive
Your busiest hour of hot water
Reset

Result

65 gallons or more

Peak hour demand is 65 gallons. Look for a tank with a first-hour rating of at least 65 gallons.

  • Shower: 3 × 20 = 60 gallons
  • Shaving: 1 × 2 = 2 gallons
  • Hand dishwashing or food prep: 1 × 3 = 3 gallons

An estimate based on average figures, for storage tank and heat pump water heaters with a tank. It does not size a tankless water heater and does not replace a plumber's assessment.

Formula

gallons for each use = average gallons per use × times used in the busiest hour
peak hour demand = the sum of all uses
first-hour rating to look for = peak hour demand, or more

Assumptions and their source

The method and every number in this calculator come from the US Department of Energy page Sizing a New Water Heater. The Department removed its Energy Saver pages from energy.gov in July 2026, so the link goes to the last archived copy, captured on July 2, 2026 and read on November 16, 2026. The worksheet on that page lists these averages.

Average gallons of hot water per use, from the US Department of Energy worksheet for estimating peak hour demand (archived July 2, 2026).
UseGallons per use
Shower20
Shaving2
Hand dishwashing or food prep3
Automatic dishwasher7
Clothes washer, top-loader25
Clothes washer, H-axis (front-loader)15
  • These are averages. The worksheet notes that its estimates are averages drawn from a variety of published information. A long shower or an older shower head uses more.
  • The worksheet has no line for a bath. This calculator does not add one, because the source gives no figure for it.
  • The number of people is used only as a check. The Department's method asks you to keep household size in mind when picking the busiest hour, but it has no formula based on people or bathrooms. The calculator flags the result if you enter more showers than people.
  • Peak hour demand is not daily use. The worksheet estimates one hour, not the whole day.

Worked example

This is the example on the Department of Energy page. On a weekday morning a household takes three showers, one person shaves, and someone washes dishes by hand once.

  1. Showers: 3 × 20 = 60 gallons.
  2. Shaving: 1 × 2 = 2 gallons.
  3. Hand dishwashing: 1 × 3 = 3 gallons.
  4. Peak hour demand: 60 + 2 + 3 = 65 gallons.

The household should look for a first-hour rating of 65 gallons or more. The archived Department page prints 66 gallons as the total for this same example. The three lines add up to 65, which is what this calculator returns.

What a first-hour rating is

The first-hour rating is the number of gallons of hot water a heater can supply in one hour, starting with a full tank of hot water. It is not the same as the size of the tank. It depends on the tank capacity, the heat source and the size of the burner or heating element, so two tanks of the same size can have different ratings. A heater that reheats quickly delivers more in an hour than its tank holds.

According to the Department of Energy page, the rating appears on the EnergyGuide label as Capacity (first hour rating), at the top left. The page notes that the label is required on conventional storage water heaters but not on heat pump water heaters. For those, look in the manufacturer's product literature.

Finding your busiest hour

Think about a normal weekday and pick the hour when the most hot water is used. For many households that is the morning, when several people shower in a row. For others it is the evening, with showers, a dishwasher run and a load of laundry close together. Count only what really happens inside that one hour. If you are unsure between two patterns, run the calculator for both and use the higher result.

A heater sized well below your peak hour demand will run out during that hour. One sized far above it costs more to buy and keeps more water hot than you use. The goal is a rating that meets the demand.

Tankless and heat pump water heaters

Heat pump water heaters with a tank are sized the same way, by first-hour rating against peak hour demand. Tankless water heaters are sized differently. The Department of Energy page explains that they are rated by the temperature rise they can achieve at a given flow rate. You add up the flow, in gallons per minute, of the fixtures you expect to run at the same time, and work out the temperature rise from your incoming water temperature to the temperature you want. This calculator does not do that. For a system that heats both water and the house, the Department advises consulting a qualified contractor.

What this estimate does not cover

  • Tankless and solar water heater sizing.
  • Fuel type, efficiency, running cost or purchase price.
  • Whether your home's gas supply, venting, wiring or space suits a particular heater.
  • Installation, which for gas and electrical connections belongs to a licensed professional.